Old Hydrostar Thermal Analysis Models
Design and orbit as of Sept. 96
Click on any image to see the full size image. All temperatures in degrees C.
Beta 90 average case (static), k (of Gr-Ep) = 6 Btu/hr-ft-F
Beta 90 average case, k (of Gr-Ep) = 90 Btu/hr-ft-F
Beta 60 average case, k = 90 Btu/hr-ft-F
Beta 90 transient case, k = 90, Time = 0.8 hrs
Beta 60 transient case, k = 90, Time = 0.2, 0.4, 0.8 hrs
Return to STAR main page
Created: September 10, 1996
Content Last Updated: September 10, 1996
By: r.m.amundsen@larc.nasa.gov
Site last reviewed: April 20, 2009.
Responsible NASA Official: Ruth M. Amundsen, Structural and Thermal Systems Branch, Systems Engineering Directorate,
Ruth.M.Amundsen@nasa.gov, (757) 864-7044
Site Curator: Ruth M. Amundsen, Structural and Thermal Systems Branch, Systems Engineering Directorate,
Ruth.M.Amundsen@nasa.gov, (757) 864-7044
Privacy Statement
Feedback on Langley Products and Services